TRA

  • Model TRA load cell measure the torque of continuous rotatin object.
  • Platinum coated connector provides long term signal stability and high accuracy.
  • These models are most appropriate for industrial measurement.
  • Applications Include   the performance tester for automotive components such as clutchs, transmissions, motors and pumps.
  • Option :  Foot mount.

Description

SPECIFICATIONS

tra

DIMENSIONS TABLE

Specifications Accuracy
Rated capacity(R.C) 1~300㎏f-m
(9.807N-m~2.942kNm)
Rated output(R.O) 1.5mV/V±1%(1~5㎏f-m:1mV/V)
Nonlinearity 0.3%R.O.
Hysteresis 0.2%R.O.
Reperatability 0.3%R.O.
Excitation recommended 10V
Terminal resistance 350Ω±1%
Insulation resistance bridge 200㏁
Temperature effect, on rated output 0.2% Load/10℃
Temperature effect, on zero balance 0.3% R.O/10℃
Safe overload 120% R.C.
Cable length φ7.4core coble 3m

SPECIFICATIONS

unit:mm

Model Capacity A B C D E F φG φH J K L M N P Q R Weight
(kg)
TRA-1K 1kgf-m
(9.807N-m)
203 43 117 38 5 35 18 85 90 50 7 17 7 M6 15 5×5 3
TRA-2K 2kgf-m
(19.61N-m)
203 43 117 38 5 35 18 85 90 50 7 17 7 M6 15 5×5
TRA-5K 5kgf-m
(49.03N-m)
203 43 117 38 5 35 18 85 90 50 7 17 7 M6 15 5×5
TRA-10K 10kgf-m
(98.07N-m)
240 55 130 50 5 45 32 100 90 50 7 17 7 M6 15 10×8 7
TRA-20K 20kgf-m
(196.1N-m)
240 55 130 50 5 45 32 100 90 50 7 17 7 M6 15 10×8
TRA-50K 50kgf-m
(490.3N-m)
340 95 150 90 5 85 47 118 100 60 8 20 9 M8 17 12×8 12
TRA-100K 100kgf-m
(980.7N-m)
340 95 150 90 5 85 47 118 100 60 8 20 9 M8 17 12×8
TRA-200K 200kgf-m
(1.961KN-m)
360 103 154 100 3 95 63 135 100 60 8 20 9 M8 17 18×11 23
TRA-300K 300kgf-m
(2.942KN-m)
360 103 154 100 3 95 63 135 100 60 8 20 9 M8 17 18×11